Take Command can open a tab window running a serial terminal on a Windows COM port. Serial tabs use the Take Command scrollback buffer and support search, recording, annotations, terminal triggers, and accessibility features. They do not run a shell, so shell-integration prompt marks and command folding are unavailable.
1.Connect the serial device and determine its COM-port number in Windows Device Manager.
2.Select Tabs > New Serial Connection.
3.Select the port from the list, then select the required baud rate, data bits, parity, stop bits, and flow control.
4.Select Connect.
The connection dialog supplies the transport framing. For repeated connections, create a Serial profile in Tabs > Connection Manager so that the port and terminal behavior can be saved together.
Most network-device console ports use 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control (9600 8N1). Refer to the device documentation; using the wrong framing commonly produces unreadable output.
Create or edit a profile in Tabs > Connection Manager, set its type to Serial, then configure the following values:
Setting |
Description |
|---|---|
Port |
The Windows COM port, such as COM3 or COM12. |
Baud |
The line speed required by the device. |
Data bits |
Usually 8; some devices require 5, 6, or 7. |
Parity |
None, Odd, Even, Mark, or Space. |
Stop bits |
1, 1.5, or 2. |
Flow control |
None, RTS/CTS, or XON/XOFF. |
Newline |
The terminator used for sent input and normalized received text: CR, LF, CRLF, or None. |
Local echo |
Displays transmitted data locally when the device does not echo it. |
Input mode |
Direct, Readline, or Hex. |
Output mode |
Text or Hex. |
Timestamp |
Adds a timestamp to each received line. |
Profile changes apply only to subsequently opened tabs. Existing serial tabs keep the settings with which they were opened.
Profiles are stored in TCMD.INI. The following example creates a reusable router-console profile:
[Profile.RouterConsole]
Type=Serial
Port=COM3
Baud=9600
DataBits=8
Parity=None
StopBits=1
FlowControl=None
Newline=CRLF
LocalEcho=No
InputMode=Direct
OutputMode=Text
Timestamp=ISO8601
Valid values are:
Key |
Valid values |
|---|---|
Parity |
None, Odd, Even, Mark, Space |
StopBits |
1, 1.5, 2 |
FlowControl |
None, RTS/CTS, XON/XOFF |
Newline |
CR, LF, CRLF, None |
LocalEcho |
Yes, No |
InputMode |
Direct, Readline, Hex |
OutputMode |
Text, Hex |
Timestamp |
None, ISO8601, DMY, MDY, Elapsed |
Newline controls the bytes sent when you press Enter:
•CR sends carriage return (0D).
•LF sends line feed (0A).
•CRLF sends carriage return followed by line feed (0D 0A).
•None sends no terminator.
Enable Local echo only when the device does not echo typed characters itself. Disable it when characters appear twice.
•Direct sends keystrokes to the device immediately.
•Readline collects typed text locally and sends it when you press Enter.
•Hex accepts hexadecimal digit pairs and sends their byte values. This is useful for binary protocols and control bytes.
•Text displays incoming data as terminal text and interprets supported terminal control sequences.
•Hex displays incoming bytes in a hexdump. Use this for binary protocols or when the incoming encoding is not text. Hex output is displayed as data, not interpreted as terminal control sequences.
Timestamps are inserted into the terminal buffer at the beginning of each received line, so they are preserved when you copy text or save a recording.
Mode |
Format |
|---|---|
None |
No timestamp. |
ISO8601 |
UTC date and time, for example [2026-09-22T13:56:35.135Z]. |
DMY |
Local date and time in day-month-year order. |
MDY |
Local date and time in month-day-year order. |
Elapsed |
Milliseconds elapsed since the tab connected. |
For an active serial tab, select Tabs > Serial Timestamp to toggle timestamps between None and ISO8601 without reconnecting.
Use the following commands while a serial tab is active:
•Tabs > Serial Disconnect closes the port but keeps the tab and its scrollback open. It also stops automatic reconnection.
•Tabs > Serial Reconnect opens the configured port again and resumes input and output.
If a device is unexpectedly disconnected, Take Command automatically attempts to reconnect unless it was explicitly disconnected. The tab title indicates when a connection is reconnecting or disconnected.
The following optional TCMD.INI settings control defaults and reconnection:
SerialReconnect=Yes
SerialReconnectDelay=2000
SerialDefaultBaud=115200
SerialDefaultNewline=CRLF
SerialLocalEcho=No
SerialTimestamp=None
SerialReconnectDelay is in milliseconds and accepts values from 250 through 60000. These global defaults apply to the New Serial Connection dialog; saved Serial profile values take precedence for their own sessions.
To open a serial connection at startup, use:
TCMD.exe /SERIAL:COM3,115200
The baud rate is optional; when omitted, Take Command uses 115200.
Symptom |
Recommended action |
|---|---|
No ports are listed |
Confirm the adapter is connected, the driver is installed, and Device Manager shows a COM port. |
Access denied or port cannot open |
Close other terminal programs that may own the COM port, then reconnect. |
Garbled characters |
Verify baud rate, data bits, parity, and stop bits against the device documentation. |
No received output |
Check the cable type, TX/RX wiring, power, and flow-control setting. |
Typed characters appear twice |
Disable Local echo or disable device-side echo. |
Typed characters do not appear |
Enable Local echo if the device does not echo input. |
Enter has no effect |
Select the newline required by the device; CR and CRLF are common choices. |
Binary output is unreadable |
Select Hex output mode. |
A disconnected device does not reconnect |
Use Tabs > Serial Reconnect after the device is available; an explicit Serial Disconnect intentionally suppresses automatic reconnect. |
Closing a serial tab cancels pending serial I/O and closes the port. Close the tab normally rather than terminating Take Command while serial I/O is active.